To the question of the use of high-strenght concrete in compressed of tall buildings

Abstract

To the question of the use of high-strenght concrete in compressed of tall buildings

Fedorov A.V., Aksenov V.N.

Incoming article date: 09.07.2018

The article deals with the effectiveness of high-strength concrete for the design of concrete columns on the example of 20-storey residential building in Rostov-on-Don. The results of the ground floor columns calculations for different types of concrete strength are presented. The columns are presented in two variations. The first variation is 600x600 B25 from the second underground floor to the tenth floor and 500x500 B25 from the eleventh to twenty-fifth floor. The second one is 500x500 B60 from the second underground floor to the seventh floor, 400x400 B60 from the eighth to the eleventh and 400x400 B25 from the twelfth to the twentieth floor. The analysis of the study results showed the technical and economic efficiency of the use of high-strength concrete (in particular, concrete class B60) due to increasing the strength characteristics of the compressed elements. This is also due to reducing the cross-sectional size and weight of the columns, saving reinforcement, causing a reduction in the cost of elements as a whole.

Keywords: high-strength concrete, compressed elements, construction of tall buildings, columns, Lira-SAPR, calculation of structures