Development of a combined device for assessing the quality of motor oils
Abstract
Development of a combined device for assessing the quality of motor oils
Incoming article date: 01.12.2018The proposed combined device for assessing the quality of motor oils. To increase the informativeness of the output data, the device uses an optical method for analyzing the contamination of motor oils and a method for assessing contamination from changes in the dielectric constant.
Keywords: lubricant, optoelectronic device, internal combustion engine, engine oil, pollution analysis method, optical control method, dielectric constant